Harmonic Mixers

 

 FEATURES

  • 20 GHz to 350 GHz Models
  • Compact Rugged Package Design
  • Custom Units Available

Harmonic Mixers

Specifications

 RF Waveguide  Model Number

 

Designation

Frequency
Band (GHz)
Flange
UG-(  )
 Q  WR-22  33-50  383/U  ZHM 22/xx/xx/xx-xx/xx
 U  WR-19  40-60  385/UM  ZHM 19/xx/xx/xx-xx/xx
 V  WR-15  50-75  385/U  ZHM 15/xx/xx/xx-xx/xx
 E  WR-12  60-90  387/U  ZHM 12/xx/xx/xx-xx/xx
 W  WR-10  75-110  387/UM  ZHM 10/xx/xx/xx-xx/xx
 F  WR-8  90-140  387/UM  ZHM 8/xx/xx/xx-xx/xx
 D  WR-6.5  110-170  387/UM  ZHM 6.5/xx/xx/xx-xx/xx
  G  WR-5  140-220  387/UM  ZHM 5/xx/xx/xx-xx/xx

 Options Available:
  • diode bias for operations with low L.O. power
  • micrometer driven tuners
  • integrated IF amplifier
  • custom units

 Ordering Information

 

 Also specify the following: LO range ( if any )
Flange pattern ( if non standard )
IF connector ( if other than SMA )
 Example:   To order a Harmonic Mixer from 92 to 94 GHz with a minimum output power of 20 mW over the                          tuning range, a WR-10 output waveguide, and a standard UG-387/UM flange pattern,
                         specify a ZHM 10/20/93.

 
Subject to change without notice.



ZAX Millimeter Wave Corporation, 1558 Howard Access Rd, Upland, CA 91786
Tel: (909) 985-9299     e-Mail: zax@millimeterwave.com